A plasma electrolytic nitrocarburising (PEN/C) process was performed on stainless steel 316L to improve the surface properties for using as medical implants. A bath was optimised to reduce the required voltage to 150 volts. Aqueous urea-based solutions with 10% NH4Cl were prepared with slightly different amounts of Na2CO3 to optimise the electrolyte composition. The surface and the cross-section morphologies were studied by scanning electron microscopy. The microstructure and the chemical composition of samples were investigated by X-ray diffraction (XRD) and energy dispersive X-ray (EDX) techniques. The microstructure of the outer layer of the coatings was found to be a complex oxide containing Cr and Fe. The wear properties of the samples were examined by using a pin on disk wear test with Ringer0s solution and were compared with their wear properties in the ambient atmosphere. The Ringer0s solution acted as a lubricant, reducing friction coe±cient. Hardness and roughness were also studied. The bath with the composition of 10% NH4Cl and 3% Na2CO3 exhibited the best tribological properties. The results showed that the tribological properties of treated samples were improved and the wear mechanism was abrasion of the pin.
参考文献
[1] | A.L. Yerokhin, A. Leyland, C. Tsotsos, A.D. Wilson, X. Nie and A. Matthews: Surf. Coat. Technol., 2001, 142-144, 1129.[2 ] A.L. Yerokhin, X. Nie, A. Leyland, A. Matthews and S.J. Dowey: Surf. Coat. Technol., 1999, 122, 73.[3 ] P. Gupta, G. Tenhundfeld, E.O. Daigle and D. Ryabkov: Surf. Coat. Technol., 2007, 201, 8746.[4 ] M.A. Bejar and R. Henriquez: Mater. Design, 2009, 30, 1726.[5 ] M. Aliofkhazraei, A. Sabour Rouhaghdama, A. Heydarzadeh and H. Elmkhaha: Mater. Chem. Phys., 2009, 113, 607.[6 ] A. Shahryari, S. Omanovic and J.A. Szpunar: Mater. Sci. Eng. C, 2008, 28, 94.[7 ] H. Liang, B. Shi, A. Fairchild and T. Cale: Vacuum, 2004, 73, 317.[8 ] R. Pietrabissa, M. Raimondi and E.D. Martino: Med. Eng. Phys., 1998, 20, 199.[9 ] P.A. Dearnley and G. Aldrich-Smith: Wear, 2004, 256, 491.[10] F. Mahzoon, M.E. Bahrololoom and S. Javadpour: Surf. Eng., 2009, 25(8), 628.[11] C. Met, L. Vandenbulcke and M.C. Sainte Catherine: Wear, 2003, 255, 1022.[12] M. Younesi, M.E. Bahrololoom and H. Fooladfar: J. Mechanical Behav. Biomedical Mater., 2010, 3, 178.[13] M. Aliofkhazraei, C. Morillo, R. Miresmaeili and A. Sabour Rouhaghdam: Surf. Coat. Technol., 2008, 202, 5493.[14] X. Nie, C. Tsotsos, A. Wilson, A.L. Yerokhin, A. Leyland and A. Matthews: Surf. Coat. Technol., 2001, 139, 135.[15] G. Jiang, Q.A. Peng, C. Li, Y. Wang, J. Gao, S.Y. Chen, J. Wang and B.L. Shen: Surf. Coat. Technol., 2008, 202, 2749.[16] P. Gupta, G. Tenhundfeld, E.O. Daigle and D. Ryabkov: Surf. Coat. Technol., 2007, 201, 8746.[17] T. Malinova, S. Malinov and U.N. Pantev: Surf. Coat. Technol., 2001, 135, 258.[18] M.T. Wright, B. Stuart and M.D. Goodman: American Academy of Orthopedic Surgeons Symposium on Implant Wear in Total Joint Replacement: Clinical and Biologic Issues, Material and Design Considerations, Oakbrook, Illinois, USA, October 2000. |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%