Surface-grafted poly(ethylene glycol) (PEG) molecules are known to prevent protein adsorption to the surface. Nitinol samples were coated under tetraglyme ECR cold plasma conditions to enhance its biocompatibility. The modified Nitinol surfaces were characterized by high resolution ESCA and contact angle, it was demonstrated that the deposited PEG-like coatings were built up mainly of -CH2-CH2-O- linkages in surfaces. The surface wettability of the modified Nitinol was increased compared with the control surface. Human plasma protein was adsorbed on Nitinol evaluated by SEM, the protein adsorption on modified surfaces decreased rapidly. Thus, the potential benefits of cold plasma technique will be of use to the biomedical industries improving the biocompatibility of metals.

参考文献

[1] SAShaalovskaya .[J].Biomedical Materials & Engineering,1996,6:267.
[2] MNMimi;B D Ratner;Y S Sinclair .[J].Sensors and Actuators,1999,54:125.
[3] Hhessand;V V ogel .[J].Reviews in Molecular Biotechnology,2001,82:67.
[4] YHanein .[J].Sensors and Actuators,2001,81:49.
[5] SZhang;G Wright;Y Yang .[J].Biosensors and Bioelectronics,2000,15:273.
[6] RDVale;R A Milligan .[J].科学(上海),2000,288:88.
[7] DRatnerandASHoffman .[J].Journal of Biomaterials Science-Polymer Edition,1992,4:3.
[8] NLozec;D Persson;A Nazarov;D Thierry .[J].Journal of the Electrochemical Society,2002,149:403.
[9] JMHarris.Introduction to biotechnical and biomedical applications of polyethylene glycol chemistry[M].Plenum,New York,1992:14.
[10] CDJames;R Davis;M Meyer;A Turner and S Turner .[J].IEEE Transactions on Biomedical Engineering,2000,47:17.
[11] ARDenes;E B Somers;Amy C L Wong;F Denes .[J].Journal of Applied Polymer Science,2001,81:3425.
[12] JCMcDonald;D C Duffy;J R Anderson;D T Chiu .[J].Electrophoresis,2000,21:27.
[13] GPLopez;B D Ratner;C D Tidwell .[J].Journal of Biomedical Materials Research,1992,26:415.
[14] JunYANGandJianhuaWANG .[J].Journal Wuhan Institute Chem Technol,2003,25:47.
[15] Thierry;M Tabrizian;G Savadogo;L Yahia .[J].Journal of Biomedical Materials Research,2000,49:88.
[16] AWilsery;P Gregsov;L Peter .[J].Biomaterials,1991,12:970.
[17] TLizhen;J Bauer;W C Crone;R M Albrech.[A].Milwaukee WI USA,2002
[18] CShih;S Lin;K Chung;Y Chen and Y Su .[J].Journal of Biomedical Materials Research,2000,52:323.
[19] MAmijiandKPark .[J].Biomaterials,1992,12:682.
[20] CThomas;D S Gladwin;W F Robert .[J].BIOMATERIALS,2000,21:699.