采用火灾动力学模拟软件FDS对大型地下车库的火灾情景进行了数值模拟,分别讨论了隔烟卷帘、水喷淋、排烟风机以及不同措施联合作用下的消防效果.结果表明,隔烟卷帘和水喷淋都能起到良好的消防效果并且联合作用时效果更佳;而机械排烟措施则不然,它反而在一定程度上加剧了火灾的发展,与前两种措施联合作用时仍无明显效果.这说明在地下车库中,当火灾发生时,排烟系统的启动要慎重,否则可能会加剧火灾的蔓延.
参考文献
[1] | W K Chow .Simulation of Tunnel Fires Using a Zone Model[J].Tunnelling and Underground Space Technology,1996,11(02):221-236. |
[2] | Ingason H;Gustavsson S;Dahlberg M .Heat Release Rate Measurements in Tunnel fires,Swedish National Testing and Research Institute[R].Swweden,SP Report,1994. |
[3] | R O Carvel;A N Beard;P W Jowitt .The Influence of Longitudinal Ventilation Systems on Fires in Tunnels[J].Tunnelling and Underground Space Technology,2001,16(01):3-21. |
[4] | Ida Larsson;Haukur Ingason;Magnus Arvidson .SPSwedish National Testing and Research Institute[R].SP Report,2002. |
[5] | McGrattan K B;Baum H R;Rehm R G et al.Fire Dynamics Simulator (Version 3)-Technical Reference Guide[R].Technical Report NISTIR 6783,National Institute of Standards and Technology Gaithersburg,MD 20899,1997. |
[6] | McGrattan K B;Baum H R;Rehm R G et al.Fire Dynamics Simulator-User's Guide[R].Technical Report NISTIR 6784,National Institute of Standards and Technology,Gaithersburg,MD,2001. |