研制了两种用于检测室温样品的超导量子干涉器(SQUID)扫描磁场显微镜(以下简称扫描SQUID显微镜),一种使用常规低Tc(Nb)SQUID器件,另一种使用高温(YBCO)SQUID器件.SQUID安装在内杜瓦底部的冷指底端,外杜瓦底部有60~75微米厚的白宝石窗口,被测样品处于室温状态位于窗口下,SQUID与被测样品之间的间距通过波纹管的伸缩进行调节.常规低Tc(Nb)器件系统的空间分辨率优于140μm,磁场灵敏度优于3pT/Hz1/2,高温(YBCO)器件系统的空间分辨率~500μm,磁场灵敏度~46pT/Hz1/2.两者均能长时间稳定地工作在无屏蔽环境中.利用两台扫描SQUID显微镜,进行了多种有应用价值的磁成像实验和无损检测研究.
参考文献
[1] | An overview to SQUIDs is given for example by J.Clarke Proceedings of the NATO ASI on SQUID Sensors: Fundamentals, Fabrication and Applications[C].Kluwer, Dordrecht,1996:1-55. |
[2] | T J Show K Schenga et al.High-Tc SQUID Microscope Study of the Effects of Microstructure and Deformation on the Remannet Magnetization of Steel[J].IEEE Transactions on Applied Superconductivity,1999,9(02):4107-4110. |
[3] | M. v. Kreutzbruck;U. Baby;A. Theiss;M. Muck;C. Heiden .Inspection of aircraft parts with high remanent magnetization by eddy current SQUID NDE[J].IEEE Transactions on Applied Superconductivity: A Publication of the IEEE Superconductivity Committee,1999(2 Pt.3):3805-3808. |
[4] | L N Vu;M S Wistrom;D J Van Harlingen .Imaging of magnetic vortices in superconducting networks and clusters by scanning SQUID microscopy[J].Applied Physics Letters,1993,63(12):1693-1695. |
[5] | Wikswo J.P. Jr. .SQUID magnetometers for biomagnetism and nondestructive testing: important questions and initial answers[J].IEEE Transactions on Applied Superconductivity: A Publication of the IEEE Superconductivity Committee,1995(2):74-120. |
[6] | 丁红胜,张峰会,颜晓明,韩士吉,董世迎,于洪伟,陈赓华,何豫生.A scanning superconducting quantum interference device microscope for room temperature samples[J].中国物理(英文版),2002(11):1135-1139. |
[7] | 孟树超,邓鹏,聂瑞娟,谢飞翔,马平,刘乐原,王守证,戴远东.用于HTc rf SQUID的新型超导共面谐振器[J].低温物理学报,2002(03):179-182. |
[8] | 张升原,谢飞翔,刘新元,马平,王守证,戴远东.一种消除HTc SQUID系统中50Hz工频干扰的有效方法[J].低温物理学报,2002(04):264-267. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%