10CrMo910 and 316 stainless steel are widely adopted in high temperature structures of power generations, chemical processing plants and petroleum refineries. In this work, a total of 10000 hour tensile creep test on 16 specimens of such two materials was conducted at 550℃. On the basis of the experimental results, the isochronous stress-strain curves and time-dependent failure assessment curves of the two materials were given. Finally, the formulae of time dependent failure assessment curve for 10CrMo910 and 316 stainless steel corresponding to long-term creep cases, which could be utilized in the high temperature defects assessment, were established. The procedure for defining the time-dependent failure assessment curves was also presented.
参考文献
[1] | R A Ainsworth;R Hales;P L Budden;D.C. Martin.Assessment Procedure for the High Temperature Response of Structures[M].Assessment Procedure R5,Issue 2,Revision,Nuclear Electric Ltd.,Gloucester,UK,April,1996:1. |
[2] | F Z Xuan;S D Tu;Z D Wang .[J].Nuclear Power Engineering,2003,6:508. |
[3] | ProcedureR6.Assessment of the Integrity of Structures Containing Defects[M].R6-Revision 4,NuclearElectric Ltd,Gloucester,UK,April,2001:1. |
[4] | CaseofASMEBoilerandPressureVesselCode.Components in Elevated Temperature Service[M].Case N47-29, Section III - Class 1, ASME, New York, Dec,1990:1. |
[5] | AFCEN .Design and Construction Rules for Mechanical Components of FBR Nuclear Island[Z].RCC-MR(AFCEN, Paris,1985. |
[6] | F·Z·Xuan;S·T·Tu;Z·D·Wang.in Fracture Mechanics 2003[A].East China University of Science and Technology Press,Shanghai,China,2003:119. |
[7] | GB 2030-1980.GB 2030-1980.Standard Test Method for Measurement of Creep Tensile Deformation in Metals[S].北京:中国标准出版社,1981. |
[8] | D A Miller .AGR Materials Data Handbook[Z].Data Handbook R66, Issue 2, British Energy Generation Ltd,1992. |
- 下载量()
- 访问量()
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%