采用一种高压脉冲绝缘老化试验系统,模拟变频器对变频调速牵引电机定子绕组绝缘材料--聚酰亚胺薄膜进行脉冲电压幅值-温度、频率-温度和频率-电压联合老化试验,利用一元二参数Weibull分布统计分析了3种老化条件下的绝缘寿命试验数据,提出了脉冲下绝缘材料的电热联合老化寿命模型.

参考文献

[1] Jeremy C. G. Wheeler .Effects of Converter Pulses on the Electrical Insulation in Low and Medium Voltage Motors[J].IEEE Electrical Insulation Magazine,2005(2):22-29.
[2] Weijun Yin .Failure mechanism of winding insulations in inverter-fed motors[J].IEEE Electrical Insulation Magazine,1997(6):18-23.
[3] Kaufhold M.;Borner G. .Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters[J].IEEE Electrical Insulation Magazine,1996(5):9-16.
[4] 佟来生,吴广宁,温凤香.变频牵引电机端子过电压产生原理及影响因素[J].西南交通大学学报,2005(05):673-676.
[5] 温凤香,吴广宁,佟来生,何恩广.高速机车牵引电机定子绕组匝间电压分布特性的仿真研究[J].电工技术学报,2005(03):30-35.
[6] 何恩广,周升,刘学忠,徐传骧,陈炳正.PWM变频电机绝缘技术的研究进展[J].绝缘材料,2002(04):18-25.
[7] Simoni L A .General Approach to the Endurance of Electrical Insulation Under Temperature and Voltage[J].IEEE Transactions on Electrical Insulation,1973,8(03):76-86.
[8] Simoni L A .General Eqution of the Decline in the Electric Strength for Combined Thermal and Electrical Stresses[J].IEEE Transactions on Electrical Insulation,1984,19(01):45-52.
[9] Ramu T S .On the Estimation of Power Apparatus Insulation Under Combined Electrical and Thermal Stress[J].IEEE Transactions on Electrical Insulation,1985,20(01):70-78.
[10] Bahder G .Physical Model of Electrical Aging and Breakdown of Extruded Polymeric Insulated Power Cables[J].IEEE Transactions on Power Apparatus and Systems,1982,101(06):1379-1385.
[11] 李忠华,尹毅,朱军,屠德民.聚合物绝缘电热联合老化的陷阱理论和实验验证[J].中国电机工程学报,1999(02):70-74.
[12] Mazzani G;Montanari G C;Dissado L A .A Spacechaarge Life Modil for AC Electrieal Aging of Polymers[J].IEEE Transactions on Dielectrics and Electrical Insulation,1999,6(06):864-876.
[13] 佟来生,吴广宁,林同光,郭育华,张国钦.一种用于脉冲绝缘老化试验的高压脉冲电源[J].高电压技术,2005(10):1-2,14.
[14] 蒋仁言.威布尔模型族特性、参数估计和应用[M].北京:科学出版社,1998
[15] Kaufhold M.;Borner G. .Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters[J].IEEE Electrical Insulation Magazine,1996(5):9-16.
[16] Bonnet A H.Comparison Between Insulation System Available for PWM-inverter-fed Motors[J].IEEE Transactions on Industry Applications,1997(05):1331-1334.
[17] D. Fabiani;G. C. Montanari;A. Cavallini;G. Mazzanti .Relation Between Space Charge Accumulation and Partial Discharge Activity in Enameled Wires Under PWM-like Voltage Waveforms[J].IEEE transactions on dielectrics and electrical insulation: A publication of the IEEE Dielectrics and Electrical Insulation Society,2004(3):393-405.
[18] Bentley J.M.;Link P.J. .Evaluation of motor power cables for PWM AC drives[J].IEEE Transactions on Industry Applications,1997(2):342-358.
[19] Weijun Yin.Critical Factors for Early Failure of Magnet Wires in Inverter-fed Motor[A].New york USA,1995:258-261.
[20] Weijun Yin .Dielectric properties of an improved magnet wire for inverter-fed motors[J].IEEE Electrical Insulation Magazine,1997(4):17-23.