简述了新型具有半导电层的外层接地绕组电缆的应用,介绍了绕组电缆及其接地系统的结构,分析了绕组电缆接地电流的分布规律,研究了接地电流分布对绕组电缆温升及电缆性能的影响.结果表明,采取增加接地面积、改善接地条件、降低接地电流密度和调整端部绕组电缆外半导电层电阻率等措施,可保证绕组电缆系统的可靠运行.