在时域上分析了高重频激光压制式干扰作用时激光导引头的信息处理过程.以具有抗干扰措施的激光制导系统为干扰目标,采用二极管泵浦全固体高重频激光器为干扰源干扰激光导引头,通过外场试验从系统级角度研究了高重频压制干扰与激光制导系统相互作用效应.用所记录的目标视线和系统光轴角误差数据表征相互作用效应,说明高重频激光压制干扰与激光制导系统相互作用效应表现为激光导引头的信息处理机制被破坏,不能正常给出的水平、俯仰角度误差信息,但这种破坏在压制干扰消除后即刻消除.
参考文献
[1] | Herrmann T,Klimt B,Siegel F.Slashing the costs of high-precision micromachining[J].Photonics Spectra,2004,38(6):70-72 |
[2] | Ostendorf A,Korber K,Kulik C,et al.Mirco-processing using UV solid-state laser systems with high repetition rate[C] // SPIE,2002,4830:414-419 |
[3] | Gray C,Skopp D,Wieneke B,et al.High-speed PIV using high-frequency diode-pumped solid state laser and multi-frame CCD[C] // ICIASF Record,International Congress on Instrumentation in Aerospace Simulation Facilities,2001,135-139 |
[4] | Deter C,Kraenert J.High resolution scanning laser projection display with diode pumped solid state lasers[C]// SPIE,2000,3954:175-184 |
[5] | Cai Xiping,Zhao Yuan,Huang Jianming,et al.Research on the performance of imaging laser radar[J].Optical Technique (光学技术),2001,27(1):60-62 (in Chinese) |
[6] | Kase T,Abe K,Hotta T,et al.LALT:Laser altimeter for luna exploring satellite SELENE[J].NEC Res.& Develop.,2003,44(2):175-180 |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%