针对神光Ⅲ原型激光装置上中子活化样品的传递问题,研究并设计了"跑兔"系统.介绍了神光Ⅲ原型装置上跑兔系统的结构与布局设计,采用气动方程详细计算并分析了样品传输过程中气源压力、润滑剂粘滞系数及样品盒与管壁的间距变化对样品速度变化的影响.结果表明,跑兔装置可在2.24 s的时间范围内将样品传输到指定位置,基本达到了系统设计要求.数值模拟结果可对"跑兔"系统的参数选取提供数值参考.
参考文献
[1] | Liang F L,Xie C A,Chen G R,et al.Nuclear Electronics & Detection Technology,1996,16 (4):307(in Chinese).(梁凤莲,谢春安,陈耿仁等.核电子学与探测技术,1996,16(4):307.) |
[2] | Lia X,Henkelmann R,Baumgartner F.Nuclear Instruments and Methods in Physics Research,2004,A522:470. |
[3] | Chen M,Chen J B,Xiong Y.Nuclear Electronics & Detection Technology,2004,24(6):793(in Chinese).(陈铭,陈家斌,熊勇.核电子学与探测技术,2004,24(6):793.) |
[4] | Chen M,Chen J B,Li C G.Nuclear Electronics & Detection Technology,2002,22(5):462(in Chinese).(陈铭,陈家斌,李朝光.核电子学与探测技术,2002,22(5):462.) |
[5] | Feng J,Wang D H,Yang C B,et al.High Power Laser and Particle Beams,2001,13(5):599(in Chinese).(冯杰,王大海,杨存榜等.强激光与粒子束,2001,13(5):599.) |
[6] | Cris W B,Thomas J M,John A O.Review of Scientific Instrument,2001,72(1):818. |
[7] | Edit Committee of Mechanical Engineering Manual and Electrical Engineering Manual.Mechanical Engineer Manual (Book 7 Volume 1).Beijing:Mechanical Industry Publishing Company,1989(in Chinese).(机械工程手册电机工程手册编辑委员会.机械工程师手册 (上册第7篇).北京:机械工业出版社,1989.) |