欢迎登录材料期刊网

材料期刊网

高级检索

为了实现植入式柔性神经微电极与外部记录或刺激装置的有效、可靠连接,本文提出了一种基于通孔电镀的植入式柔性神经微电极互连方法.该方法首先制作具有通孔结构的柔性互连膜,并将其通孔与待连接的植入式微电极焊接位点对准贴合,然后电镀生长导通金属,从而实现与待连接的植入武器件的柔性连接.最后本文通过SEM观察、电学性能测试、机械强度测试以及生物兼容性测试等手段对此互连方法的焊接效果进行了评价.测试结果表明本文提出的柔性微电极互连方法具有很好的可靠性和稳定性.

参考文献

[1] Ulbert I;Halgren E;Heit G;Karmos G .Multiple microelectrode-recording system for human intracortical applications.[J].Journal of Neuroscience Methods,2001(1):69-79.
[2] Heer F;Hafizovic S;Ugniwenko T;Frey U;Franks W;Perriard E;Perriard JC;Blau A;Ziegler C;Hierlemann A .Single-chip microelectronic system to interface with living cells[J].Biosensors & Bioelectronics: The International Journal for the Professional Involved with Research, Technology and Applications of Biosensers and Related Devices,2007(11):2546-2553.
[3] Sheffler LR;Chae J .Neuromuscular electrical stimulation in neurorehabilitation.[J].Muscle and Nerve,2007(5):562-590.
[4] Peckham PH;Knutson JS .Functional electrical stimulation for neuromuscular applications *.[J].Annual review of biomedical engineering,2005(0):327-360.
[5] Merrill E;Ainsworth A .Glass-coated platinum-plated tungsten microelectrodes[J].Medical and Biological Engineering and Computing,1972,10(05):662-672.
[6] Schanne O;Lavallee M;Laprade R;Gagne S .Electrical properties of glass microelectrodes[J].Proceedings of the IEEE,1968,56(06):1072-1082.
[7] Limousin P;Krack P;Pollak P;Benazzouz A;Ardouin C;Hoffmann D;Benabid AL .Electrical stimulation of the subthalamic nucleus in advanced Parkinson's disease.[J].The New England journal of medicine,1998(16):1105-1111.
[8] Serruya M;Hatsopoulos N;Paninski L;Fellows M,Donoghue J .Brain-machine interface:Instant neural control of a movement signal[J].Nature,2002,416(6877):141-142.
[9] Benabid AL;Pollak P;Gao D;Hoffmann D;Limousin P;Gay E;Payen I;Benazzouz A .Chronic electrical stimulation of the ventralis intermedius nucleus of the thalamus as a treatment of movement disorders.[J].Journal of Neurosurgery,1996(2):203-214.
[10] Loeb G .Cochlear prosthetics[J].Annual Review of Neuro-science,1990,13(01):357-371.
[11] Chow AY;Chow VY;Packo KH;Pollack JS;Peyman GA;Schuchard R .The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa.[J].Archives of Ophthalmology,2004(4):460-469.
[12] Campbell P.K.;Jones K.E. .A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array[J].IEEE Transactions on Biomedical Engineering,1991(8):758-768.
[13] Changhyun Kim;Wise K.D. .A 64-site multishank CMOS low-profile neural stimulating probe[J].IEEE Journal of Solid-State Circuits,1996(9):1230-1238.
[14] Kovacs G.T.A.;Storment C.W.;Halks-Miller M.;Belczynski C.R. Jr.;Santina C.C.D.;Lewis E.R.;Maluf N.I. .Silicon-substrate microelectrode arrays for parallel recording of neural activity in peripheral and cranial nerves[J].IEEE Transactions on Biomedical Engineering,1994(6):567-577.
[15] Stieglitz T;Beutel H;Schuettler M;Meyer J .Micromachined,polyimide-based devices for flexible neural interfaces[J].Biomedical Microdevices,2000,2(04):283-294.
[16] 周洪波,李刚,张华,孙晓娜,姚源,金庆辉,赵建龙,任秋实.简易低成本柔性神经微电极制作方法[J].光学精密工程,2007(07):1056-1063.
[17] Rodger DC;Fong AJ;Wen L;Ameri H;Ahuja AK;Gutierrez C;Lavrov I;Hui Z;Menon PR;Meng E .Flexible parylene-based multielectrode array technology for high-density neural stimulation and recording[J].Sensors and Actuators, B. Chemical,2008(2):449-460.
[18] Kathleen W. Meacham;Richard J. Giuly;Liang Guo;Shawn Hochman;Stephen P. DeWeerth .A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord[J].Biomedical microdevices,2008(2):259-269.
[19] Meyer J;Stieglitz T;Seholz O;Haberer W,Beutel H .High density interconnects and flexible hybrid assemblies foraetive biomedical implants[J].IEEE Transactions on Ad-vanced Packaging,2001,24(03):366-374.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%