介绍并研究了一种基于一维稳态热传导原理的三段稳态塞式量热计.该量热计通过测量探芯中间康铜段前、后表面上的温差来得到壁面热流密度.适合稳态、低热流状态下,驻点及大面积区长时间隔热材料上的多点测量.首先从理论上分析了三段稳态塞式量热计的稳态热流测量原理;然后采用超声速矩形湍流导管试验技术,利用等离子电弧加热器进行了表面热流测量试验.结果表明:在包含来流参数约±4%的系统误差情况下,三段稳态塞式量热计的测量重复性偏差为±7.6%,经误差分析得到该量热计的热流测量精度在5%以内.

参考文献

[1] ASTM Standard:E 457-1996.ASTM Standard:E 457-1996.Standard test method for measuring heat-transfer rate using a thermal capacitance (slug)calorimeter[S].
[2] ASTM Standard:422-1983.ASTM Standard:422-1983.Standard test method for measuring heat flux using a water-cooled calorimeter[S].
[3] ASTM Standard:E 598-1996.ASTM Standard:E 598-1996.Standard test method for measuring extreme heat-transfer rates from high-energy environments using a transient,null-point calorimeter[S].
[4] Kidd C.T.High heat flux measurements and experimental calibrations/characterizations[NASA-CP-3161][A].,1992
[5] 杨世铭;陶文铨.传热学[M].北京:高等教育出版社,1998
[6] 杨庆涛;王辉;吴礼恒.水冷塞式量热计的研制与实验[A].:618-621.
[7] H.Φ.卡扎柯夫;何康生.真空扩散焊接[M].北京:国防工业出版社,1976
[8] 李振山.测量误差与数据处理[M].计量测试研究所,1982
上一张 下一张