对目前国内外高温高压水溶液用AAg/AgCl参比电极的研究现状进行了回顾和总结,主要针对内置式参比电极和外置式参比电极的结构和存在的问题进行了讨论.两种电极在结构上的发展都是从复杂到简单实用,大量新材料和新技术的应用使参比电极的性能有了很大的提高.相比来说,内置式参比电极由于结构简单,电位稳定,比较适合用于热力学方面的研究;而外置式参比电极的结构比较复杂,适合于动力学方面的研究.并对参比电极的发展趋势进行了展望.
参考文献
[1] | Dobson J V;Firman R E;Thirsk H R .The behaviour of cells using silver/silver chloride and skin - calomel electrodes at temperature from 25℃ to 200℃ and 1 bar to 2k bar pressure[J].Electrochimica Acta,1971,16:793-809. |
[2] | 周伟舫.电化学测量[M].上海:上海科学技术出版社,1985 |
[3] | Ives D J G;Janz G J.Reference Electrodes - Theory and Practice[M].New York and London:Academic Press,1961 |
[4] | MacDonald D D .Reference electrodes for high temperatuire aqueous systems - a review and assessment[J].Corrosion,1978,34(03):75-84. |
[5] | Katsuhisa Sugimoto .Reference electrodes for high temperature high pressure aqueous solutions and their application to corrosion studies[J].Boshoku Gijutsu,1980,29:521-533. |
[6] | Reference electrode for use at high temperatures and pressures[P].US:4116798,1978. |
[7] | Reference electrode assembly of a silver/silver chloride construction[P].US 5034113,1989. |
[8] | Magar I J;Morris P E .The construction and performance of a silver/silver chloride reference electrode for high temperature aqueous environments[J].Corrosion,1976,32:374-377. |
[9] | 卢建树.Ag|AgCl参比电极的研制[J].浙江工业大学学报,1991(02):80. |
[10] | Wilde B E .A assembly for electrochemical corrosion studies in aqueous environments at high temperature and pressure[J].Corrosion,1967,23:331-334. |
[11] | Sintered ceramic article with porous region[P].US:4500413,1985. |
[12] | Katsuhisa Sugimoto;Saiko Soma .Anew designed Ag - AgCl internal reference electrode and its application to measurements of anodic polarization curves for type 304L stainless steel in high tempera ture aqueous solutions[J].Boshoku Gijutsu,1982,31:574-581. |
[13] | Reference electrode probe for use in aqueous environments of high temperature[P].US:5262038,1991. |
[14] | Huang S;Daehling K;Carleson T E .Construction and calibration of an internal silver/silver chloride reference electrode for supercritical fluid studies[J].Corrosion,1991,47(03):185-188. |
[15] | Agrawal A K;Staehle R W .A silver-silver chloride reference electrode for the high temperature and high pressure electrochemistry[J].Corrosion,1977,33(11):418-420. |
[16] | Indig M E;Mcilree A R .High temperature electrochemical studies of the stress corrosion of type 304 stainless steel[J].Corrosion,1979,35:288-292. |
[17] | Rugged electrode for electrochemical measurements at high temperatures and pressures[P].US:5516413,1993. |
[18] | Reference electrode with annular junction[P].US 5234570,1991. |
[19] | Danielson M J .The construction and thermodynamic performance of an Ag - AgCl reference electrode for use in high temperature aqueous environments containing H2 and H2S[J].Corrosion,1979,35:200-204. |
[20] | MacDonald D D;Scott A C;Wentrcek P .External reference electrodes for use in high temperature aqueous system[J].Journal of the Electrochemical Society,1979,126:908-911. |
[21] | Katsumi Kushiya;Katsuhisa Sugimoto;Tatsuhiko Ejima .Electrochemical polarization behavior of sensitized SUS 304 stainless steel in high temperature water[J].Nihon Kinzoku Gakkaishi,1978,42:1109-1112. |
[22] | Long life reference electrode[P].US:4818366,1987. |
[23] | Koji Tachibana .A new pressure - balanced outer reference electrode with oxidized zircaloy tube container for corrosion studies in high - temperature - high - pressure aqueous solution and its application to obtaining polarization curves[J].Boshoku Gijutsu,1985,34:125-131. |