通过测量镦头自腐蚀电位等参数,判断吊杆钢丝的腐蚀概率;以吊杆钢丝和CCMP-I检测探头分别作为研究电极,运用恒电量技术检测获得Rp值和Tafel常数,从而计算出腐蚀速率icorr.检测结果表明:压浆对增强钢丝的保护有成效;由于锈蚀原因不同,各短吊杆位置钢丝的锈蚀速率差异很大.
参考文献
[1] | Rodriguez P et al.Method for studying corrosion in reinforced concrete[J].Magazine of Concrete Research,1994(46):81. |
[2] | Glass G K et al.An assessment of the coulostatic method applied to the corrosion of steel in concrete[J].Corrosion Science,1995,37(04):597. |
[3] | Rodriguez P et al.Use of the coulostatic method for measuring corrosion rates of embedded metal in concrete[J].Magazine of Concrete Research,1994(46):91. |
[4] | A. M. Hassanein;G. K. Glass;N. R. Buenfeld .The use of small electrochemical perturbations to assess the corrosion of steel in concrete[J].NDT & E international: Independent nondestructive testing and evaluation,1998(4):265-272. |
[5] | 赵永韬,吴建华,赵常就.评价混凝土中钢筋腐蚀的恒电量技术[J].电化学,2001(03):258-266. |
[6] | Andrade C;Gonzalez J A .Quantitative measurements of corrosionrate of reinforcing steel embedded in concrete using polarization re-sistance measurements[J].WerKstoffe und Korrosion,1978,29:515. |