采用恒压直流阳极氧化法对医用镍钛合金进行了表面改性处理,目的是有效降低其表面镍含量,改善生物相容性.通过表面形貌、化学成分以及晶相分析发现,改性后的表面氧化层具有特殊的连通多孔结构,平均孔径为80~120 nm,厚度为5~12 μm;该层主要由非晶相TiO2组成,200~400C 30 min热处理可使部分非晶相转化为晶相金红石结构.另外,改性后的表面在Hank's模拟体液中的Ni离子溶出量也比改性前大大减少.综合来看,本文工艺实现了对医用镍钛合金在微观结构和性能上的双重改善,是比较有应用潜力的表面改性工艺.
参考文献
[1] | 赵英;郭文杰;宋焱峰;侯一平.镍及其合金植入大鼠体内后镍的代谢变化[J].现代预防医学,2007(20):3830-3832,3839. |
[2] | 刘辉;憨勇.医用多孔金属的制备及其生物活化研究进展[J].中国材料进展,2012(5):40-56. |
[3] | C.L Chu;R.M. Wang;L.H. Yin;Y.P. Pu;P.H. Lin;Y.S. Dong;C.Y. Chung;K.W.K. Yeung;P.K. Chu.Effects of anodic oxidation in H_2SO_4 electrolyte on the biocompatibility of NiTi shape memory alloy[J].Materials Letters,200820(20):3512-3514. |
[4] | Huang CJ;Xie YB;Zhou LM;Huang HT.Enhanced surface roughness and corrosion resistance of NiTi alloy by anodization in diluted HF solution[J].Smart Materials & Structures,20092(2):024003-1-024003-6-0. |
[5] | Zhendi Yang;Xiaojin Wei;Wei Gao;Peng Cao.Anodization of NiTi alloy in an ethylene glycol electrolyte[J].Surface & Coatings Technology,2014:142-147. |
[6] | F.T. Cheng;P. Shi;H.C. Man.Nature of oxide layer formed on NiTi by anodic oxidation in methanol[J].Materials Letters,200512(12):1516-1520. |
[7] | G. Rondelli;P. Torricelli;M. Fini.In Vitro Corrosion Study by EIS of an Equiatomic NiTi Alloy and an Implant Quality AISI 316 Stainless Steel[J].Journal of biomedical materials research, Part A,20062(2):320-324. |
[8] | P. Shi;F.T. Cheng;H.C. Man.Improvement in corrosion resistance of NiTi by anodization in acetic acid[J].Materials Letters,200711/12(11/12):2385-2388. |
[9] | Kawakita J;Stratmann M;Hassel AW.High voltage pulse anodization of a NiTi shape memory alloy[J].Journal of the Electrochemical Society,20076(6):C294-C298. |
[10] | M.H. Wong;F.T. Cheng;H.C. Man.Characteristics, apatite-forming ability and corrosion resistance of NiTi surface modified by AC anodization[J].Applied Surface Science: A Journal Devoted to the Properties of Interfaces in Relation to the Synthesis and Behaviour of Materials,200718(18):7527-7534. |
[11] | Neupane MP;Park IS;Lee MH.Influence of heat treatment on morphological changes of nano-structured titanium oxide formed by anodic oxidation of titanium in acidic fluoride solution.[J].Bio-medical materials and engineering,20091(1):77-83. |
[12] | Sul YT.The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant.[J].Biomaterials,200322(22):3893-3907. |
[13] | Regonini, D;Jaroenworaluck, A;Stevens, R;Bowen, CR.Effect of heat treatment on the properties and structure of TiO2 nanotubes: phase composition and chemical composition[J].Surface and Interface Analysis: SIA: An International Journal Devoted to the Development and Application of Techniques for the Analysis of Surfaces, Interfaces and Thin Films,20103(3):139-144. |
[14] | Oomman K. Varghese;Dawei Gong;Maggie Paulosse.Crystallization and high-temperature structural stability of titanium oxide nanotube arrays[J].Journal of Materials Research,20031(1):156-165. |
[15] | Qingyun Cai;Maggie Paulose;Oomman K. Varghese.The effect of electrolyte composition on the fabrication of self-organized titanium oxide nanotube arrays by anodic oxidation[J].Journal of Materials Research,20051(1):230-236. |
[16] | Shabalovskaya S;Anderegg J;Van Humbeeck J.Critical overview of Nitinol surfaces and their modifications for medical applications.[J].Acta biomaterialia,20083(3):447-467. |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%