欢迎登录材料期刊网

材料期刊网

高级检索

研究提供了一种简易、低成本的方法进行神经微电极的性能改进,来改善神经电极/神经组织的界面特性.采用电化学方法合成导电聚合物聚苯胺PA-NI和PANI-MWCNT(多壁碳纳米管)复合涂层,对神经微电极位点进行表面修饰;对修饰电极的表面形貌与电学性能进行测试,对比分析了MWCNT掺杂对PANI涂层的影响.结果表明,MWCNT掺杂改善了PANI涂层的表面形貌;与PANI修饰电极相比,PA-NI-MWCNT修饰电极界面通过的电荷量提高了近14倍,电学性能稳定性更好,在神经信号相关的1kHz频率处阻抗降低到原来的1/8,PANI-MWCNT复合涂层能更好地提高电极的电学性能.

参考文献

[1] Cogan SF .Neural stimulation and recording electrodes.[J].Annual review of biomedical engineering,2008(0):275-309.
[2] Wise K D.Wireless integrated microsystems:wearable and implantable devices for improved health care[A].,2009
[3] Keserue M;Post N;Hornig R et al.Long term tolerability of the first wireless implant for electrical epiretinal stimulation[J].ARVO Meeting Abstracts,2009,50:4226.
[4] 刘炳辛,鲁艺,王定芳,李涛,周琴,曹余良,段晏文.植入式铂-铱合金微电极的修饰和植入大鼠大脑运动皮层后的阻抗测量[J].武汉大学学报(理学版),2009(03):253-257.
[5] Cogan S F;Ehrlich J;Plante T D.Penetrating microelectrode arrays with low-impedance sputtered iridium oxide electrode coatings[A].,2009:7147-7150.
[6] Green,RA;Lovell,NH;Wallace,GG;Poole-Warren,LA .Conducting polymers for neural interfaces: challenges in developing an effective long-term implant.[J].Biomaterials,2008(24/25):3393-3399.
[7] Keserü M;Feucht M;Bornfield N et al.Acute electrical stimulation of the human retina with an epiretinal electrode array[J].ACTA OPHTHALMOLOGICA,2012,90(01):e1-e8.
[8] Logothetis NK;Augath M;Murayama Y;Rauch A;Sultan F;Goense J;Oeltermann A;Merkle H .The effects of electrical microstimulation on cortical signal propagation.[J].Nature neuroscience,2010(10):1283-1291.
[9] 张华,朱壮晖,吴蕾,周洪波,孙晓娜,周亮,李刚,金庆辉,赵建龙.导电聚合物修饰的柔性神经微电极的制备与界面性质[J].功能材料与器件学报,2010(05):457-464.
[10] Biran R;Martin DC;Tresco PA .The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull.[J].Journal of biomedical materials research, Part A,2007(1):169-178.
[11] George C McConnell;Howard D Rees;Allan I Levey;Claire-Anne Gutekunst;Robert E Gross;Ravi V Bellamkonda .Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration[J].Journal of neural engineering,2009(5):056003:1-056003:12.
[12] Xie D.;Jiang YD.;Pan W.;Li D.;Wu ZM.;Li YR. .Fabrication and characterization of polyaniline-based gas sensor by ultra-thin film technology[J].Sensors and Actuators, B. Chemical,2002(2/3):158-164.
[13] Abidian, MR;Corey, JM;Kipke, DR;Martin, DC .Conducting-Polymer Nanotubes Improve Electrical Properties, Mechanical Adhesion, Neural Attachment, and Neurite Outgrowth of Neural Electrodes[J].Small,2010(3):421-429.
[14] Abidian MR;Martin DC .Experimental and theoretical characterization of implantable neural microelectrodes modified with conducting polymer nanotubes.[J].Biomaterials,2008(9):1273-1283.
[15] Di L;Wang LP;Lu YN;He L;Lin ZX;Wu KJ;Ren QS;Wang JY .Protein adsorption and peroxidation of rat retinas under stimulation of a neural probe coated with polyaniline.[J].Acta biomaterialia,2011(10):3738-3745.
[16] Wang H J;Ji L W;Li D F et al.Characterization of nanostructure and cell compatibility of polyaniline films with different dopant acids[J].Journal of Physical Chemistry B,2008,112:2671-2677.
[17] G. G. Wallace;M. J. Higgins;S. E. Moulton .Nanobionics: the impact of nanotechnology on implantable medical bionic devices[J].Nanoscale,2012(15):4327-4347.
[18] Raj Kishore Sharma;Lei Zhai .Multiwall carbon nanotube supported poly(3,4-ethylenedioxythiophene)/manganese oxide nano-composite electrode for super-capacitors[J].Electrochimica Acta,2009(27):7148-7155.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%