在研究一种新型桥路型高温超导限流器的限流原理的基础上,研制开发了一台三相600V、故障电流峰值100A的实验室样机.本文介绍了该限流器的功率电路、控制器、低温容器和高温超导磁体等部分的结构特点和功能.在三相系统中进行了各种短路故障限流实验,结果表明该限流器有较强的限流能力和重合闸能力,说明新型高温超导限流器的研究对改善电网动态性能和提高电网电能质量有十分重要的意义.
参考文献
[1] | 叶林,林良真.桥式超导故障限流器的短路试验研究[J].电力系统自动化,1999(18):9-11. |
[2] | Salim K.M.;Hoshino T.;Nishikawa M.;Muta I.;Nakamura T. .Preliminary experiments on saturated DC reactor type fault current limiter[J].IEEE Transactions on Applied Superconductivity: A Publication of the IEEE Superconductivity Committee,2002(1):872-875. |
[3] | S H Lim;H G Kang et al.[J].Materials Science and Engineering,2003,B102:348-351. |
[4] | Takao Sato;Mitsugi Yamaguchi;Satoshi Fukui;Yukihito Watanabe;Toshiro Matsumura;Hirotaka Shimizu .A study on DC S/N transition type superconducting fault current limiting interrupter[J].IEEE Transactions on Applied Superconductivity: A Publication of the IEEE Superconductivity Committee,2003(2 Pt.2):2088-2091. |
[5] | Toshifumi Ise;Nguyen Hong Nguyen;Sadatoshi Kumagai .Reduction of inductance and current rating of the coil and enhancement of fault current limiting capability of a rectifier type superconducting fault current limiter[J].IEEE Transactions on Applied Superconductivity: A Publication of the IEEE Superconductivity Committee,2001(1 Pt.2):1932-1935. |