近年来,循环肿瘤细胞(CTCs)研究得到了越来越多的关注,许多研究报告已经证实其在肿瘤转移的早期诊断、治疗方案选择、个体化治疗及探索肿瘤转移机制等方面具有潜在的价值,然而CTCs在循环系统中的含量极低,这成为限制其临床相关应用的主要难点.微流控芯片技术具有低成本、快速、高通量及操作简单等优势,利用微流控芯片可实现CTCs的高速、高回收率、高纯度的分选富集,近年来得到广泛的关注.本文综述了近年来在微流控芯片内进行CTCs分选富集的研究并探讨了各种方法的优缺点,并在本研究团队的研究基础上进行了展望.
参考文献
[1] | Gupta G P,Massague J.Cell,2006,127 (4):679 |
[2] | Zhang P,SunC L,Zhang R,et al.Chinese Journal of Chromatography(张鹏,孙长龙,张人,等.色谱),2013,31(6):518 |
[3] | Du J H,Liu Z B,Zhang W,et al.Chinese Journal of Health Laboratory Technology(杜晶辉,刘宗彬,张望,等.中国卫生检验杂志),2013,23(6):1364 |
[4] | Racila E,Euhus D,Weiss A J,et al.Proc Natl Acad Sci USA,1998,95(8):4589 |
[5] | Lianidou E S,Markou A.Clin Chem,2011,57(9):1242 |
[6] | Zhe X,Cher M L,Bonfil R D.Am J Cancer Res,2011,1(6):740 |
[7] | Ke F,Wu J M,Yao J E,et al.Chinese Journal of Laboratory Medicine(柯峰,吴健民,姚见儿,等.中华检验医学杂志),2007,30(1):77 |
[8] | Miller M C,Doyle G V,Terstappen L W.J Oncol,2010,DOI:10.1155/2010/617421 |
[9] | Liotta L A,Saidel M G,Kleinerman J.Cancer Res,1976,36(3):889 |
[10] | Stone H A,Stroock A D,Ajdari A.Ann Rev Fluid Mech,2004,36:381 |
[11] | LinB C,Qin J H.Microfluidic Chip Laboratory.Beijing:Science Press(林炳承,秦建华.微流控芯片实验室.北京:科学出版社),2006 |
[12] | Hughes A D,Mattison J,Powderly J D,et al.J Vis Exp,2012,15(64):4248 |
[13] | Nagrath S,Sequist L V,Maheswaran S,et al.Nature,2007,450(7173):1235 |
[14] | Stott S L,Hsu C H,Tsukrov D I,et al.Proc Natl Acad Sci USA,2010,107(43):18392 |
[15] | Wang S,Liu K,Liu J,et al.Angew Chem Int Ed Engl,2011,50(13):3084 |
[16] | KangJH,Krause S,Tobin H,et al.Lab Chip,2012,12(12):2175 |
[17] | Cristofanilli M,Budd G T,Ellis M J,et al.NEngl J Med,2004,351(8):781 |
[18] | Lin M X,Hyun K A,Moon H S,et al.Biosens Bioelectron,2013,40(1):63 |
[19] | Mikolajczyk S D,Millar L S,Tsinberg P,et al.J Oncol,2011,DOI:10.1155/2011/252361 |
[20] | Lustberg M,Jatana K R,Zborowski M,et al.Recent Results Cancer Res,2012,195:97 |
[21] | Huang SB,WuMH,LinY H,etal.Lab Chip,2013,13(7):1371 |
[22] | ZhengS,Lin H,Liu J Q,et al.J Chromatogr A,2007,1162(2):154 |
[23] | Lin H K,Zheng S,Williams A J,et al.Clin Cancer Res,2010,16(20):5011 |
[24] | Liu D Y,Yan W,Zhang Q,et al.Journal of Molecular Diagnostics and Therapy(刘大渔,严伟,张琼,等.分子诊断与治疗杂志),2012,4(6):366 |
[25] | Mohamed H,Murray M,Turner J N,et al.J Chromatogr A,2009,1216(47):8289 |
[26] | Chung J,Shao H,Reiner T,et al.Adv Healthcare Mater,2012,1(4):432 |
[27] | ParkJS,SongSH,JungHI.Lab Chip,2009,9(7):939 |
[28] | Sim T S,Kwon K,Park J C,et al.Lab Chip,2011,11(1):93 |
[29] | Gossett D R,Di Carlo D.Anal Chem,2009,81:8459 |
[30] | Di Carlo D.Lab Chip,2009,9(21):3038 |
[31] | Kuntaegowdanahalli S S,Bhagat A A,Kumar G,et al.Lab Chip,2009,9 (20):2973 |
[32] | Sun J,Li M,Liu C,et al.Lab Chip,2012,12(20):3952 |
[33] | Inglis D W,Davis JA,Austin R H,et al.Lab Chip,2006,6(5):655 |
[34] | Loutherback K,Chou K S,Newman J,et al.Microfl Nanofl,2012,9(6):1143 |
[35] | Loutherback K,D' Silva J,Liu L,et al.Nat Precedings,2012,1:6861 |
[36] | Liu Z B,Huang F,Du J H,et al.Biomicrofluidics,2013,7(1):1801 |
[37] | Pethig R,Menachery A,Pells S,et al.J Biomed Biotechnol,2010,DOI:10.1155/2010/182581 |
[38] | Becker F F,Wang X B,Huang Y,et al.Proc Natl Acad Sci USA,1995,92(3):860 |
[39] | MoonHS,Kwon K,Kim S I,et al.Lab Chip,2011,11(6):1118 |
[40] | Kim S,Han S I,Park M J,et al.Anal Chem,2013,85(5):2779 |
[41] | Augustsson P,Magnusson C,Nordin M,et al.Anal Chem,2012,84(18):7954 |
[42] | Liu Z B,Zhang W,Huang F,et al.Biosens Bioelectron,2013,47C:113 |
上一张
下一张
上一张
下一张
计量
- 下载量()
- 访问量()
文章评分
- 您的评分:
-
10%
-
20%
-
30%
-
40%
-
50%