建立了同时测定食品塑料包装材料中9种紫外光稳定剂含量的高效液相色谱方法.样品用甲醇-乙酸乙酯混合溶剂超声提取,经固相萃取小柱净化后,以ZORBAX SB-C18柱(250mm×4.6 mm,5μm)为分离色谱柱,甲醇和水为流动相,梯度洗脱,以310 nm为检测波长进行定性、定量分析.该方法前处理简单、易操作,9种紫外光稳定剂分离效果良好.9种紫外光稳定剂在0.2~10 mg/L范围内呈良好的线性关系,线性相关系数大于0.999;方法检出限为0.05 ~0.1 mg/L;实际样品中的加标回收率为70.2%~89.0%,相对标准偏差为0.4%~4.5%.该方法简单、准确,能够满足食品塑料包装材料中紫外光稳定剂的检测要求.
参考文献
[1] | Wang H Y,Zhang Y J.Plastics Science and Technology(王海鹰,张玉杰.塑料科技),2009,37(12):68 |
[2] | Chen Y S.Friend of Chemical Industry(陈有双.化工之友),2007(8):35 |
[3] | Xiang X,Cheng S,Zhang J,et al.J Vinyl Technol,2010,10:23 |
[4] | Wang K C,Ning P S,Ding Z M.China Chemicals(王克昌,宁培森,丁著明.化工文摘),2008(1):48 |
[5] | Mutsuko H K,Takashi M,Toshio I,et al.Drug Chem Toxicol,2008,31:383 |
[6] | Coelho P C G,Ravenzwaay B V,Tennekes H A,et al.Skin Pharmacol Physiol,2009,22:166 |
[7] | Ema M,Fukunishi K,Matsumoto M,et al.Drug Chem Toxicol,2006,29:215 |
[8] | Sotonyi P,Merkely B,Hubay M,et al.Toxicol Sci,2004,77:368 |
[9] | Kawamura Y,Ogawa Y,Nishimura T,et al.J Health Sci,2003,49 (3):205 |
[10] | Meng PR,LiLB,SongGL.China Plastics Industry (孟平蕊,李良波,宋桂兰.塑料工业),1997(5):104 |
[11] | Zhang Y,Li J J,QianY P.Petrochemical Technology(张怡,李建军,钱玉萍.石油化工),1999,28(1):48 |
[12] | He Q S,Xu N,Li J,et al.Chinese Journal of Chromatography(何乔桑,徐娜,李晶,等.色谱),2011,29(8):762 |
[13] | Ministry of Health.Hygienic Standard for Cosmetics.Beijing:Ministry of Health of the People's Republic of China (卫生部.化妆品卫生规范.北京:中华人民共和国卫生部),2007 |
[14] | Monteiro M,Nerin C,Rubio C,et al.J High Resol Chromatogr,1998,21:317 |
[15] | Nerin C,Fernaandez C,Domeno C,et al.J Agric Food Chem,2003,51:5647 |