考察了环糊精种类、环糊精浓度、缓冲溶液pH、分离电压、温度等因素对3-苯基乳酸手性分离的影响,并对分离条件进行了优化.结果表明,采用区带毛细管电泳技术,以0.03 mol/L的羟丙基-β-环糊精为手性选择剂,0.1 mol/L的磷酸缓冲溶液(pH 5.5)为电泳缓冲溶液,26 kV的分离电压,在25 ℃下可使3-苯基乳酸对映体达到基线分离,分离度为1.51.

参考文献

[1] Urban F J,Moore B S.J Heterocycl Chem,1992,29(2):431
[2] Weckwerth W,Miyamoto K,Linuma K,Krause M,Glinski M,Storm T,Bonse G,Kleinkauf H,Zocher R.J Biol Chem,2000,275(23):17909
[3] Hemmi K,Neya M,Marusawa H,Imai K,Kayakiri N,Hashimoto M .US Patent,4921855.1990
[4] Kano S,Yuasa Y,Yokomatsu T,Shibuya S.J Org Chem,1988,53(16):3865
[5] Hashimoto Y,Kobayashi E,Endo T,Nishiyama M,Horinouchi S.Biosci Biotech Biochem,1996,60(8):1279
[6] Yamamoto T,Nozaki A,Shintani S,Ishikura S,Katagiri Y,Hara A.J Biochem (Tokyo),2000,128(1):121
[7] Armstrong D W,Gasper M P,Rundlett K L.J Chromatogr A,1995,689:285
[8] Fanali S,Aturki Z,Desiderio C,Righetti P G.J Chromatogr A,1999,838:223
[9] Nardi A,Eliseev A,Bocek P,Fanali S.J Chromatogr A,1993,638:247
[10] Schmid M G,Lecnik O,Sitte U,Gübitz G.J Chromatogr A,2000,875:307
[11] Potier I L,Tamisier-Karolak S L,Morin P H,Megel F,Taverna M.J Chromatogr A,1998,829:341
[12] Clohs L,McErlane K M.J Pharm Biomed Anal,2001,24:545
[13] Fanali S,Aturki Z.J Chromatogr A,1995,694:297
[14] Kodama S,Yamamoto A,Matsunaga A,Soga T,Minoura K.J Chromatogr A,2000,875:371