为更好的理解困扰电感耦合等离子质谱仪(ICP-MS)分析灵敏度提高的基质干扰问题,利用激光诱导荧光技术,考察了钡离子和钙离子在ICP-MS取样锥后的质量控制传递行为.通过比较分析离子在取样锥孔口及后端的径向分布,探讨了ICP功率、雾化气流速及基质干扰对取样锥后分析离子空间分布的影响.结果表明:取样锥孔口钙离子与钡离子分布类似,但取样锥后扩散状况与其相对原子质量有关,相对原子质量小的元素径向扩散更快,因此仪器检测灵敏度较低;雾化气流速越大,分析离子的传递效率越低,因此更高的进样速率在ICP-MS应用中不一定对应更高的检测灵敏度;分析离子径向分布及数量也受基质组分影响,基质干扰降低了取样锥后中心轴线上的分析离子数量,使其径向分布变得更扁平,通过截取锥的概率更低,最终使得分析离子的信号降低.

参考文献

[1] Agatemor C, Beauchemin D.Matrix effects in inductively coupled plasma mass spectrometry:a review[J].Analytica Chimica Acta, 2011(1):66-83.,2011.
[2] 谢华林 .高分辨电感耦合等离子体质谱在高纯金属分析中的应用研究[D].中南大学,2009.
[3] 张彩聪.ICP-MS法测定岩矿样品中20种痕量元素的方法研究[D].北京:中国地质大学,2003.,2003.
[4] Moses L M, Ellis W C, Jones D D, et al.Fluorescence imaging of ion distributions in an inductively coupled plasma with laser ablation sample introduction[J].Spectrochimica Acta Part B:Atomic spectroscopy, 2015 (1):47-59.,2015.
[5] Chan G C, Hieftje G M.Spatial emission profiles for flagging matrix interferences in axial-viewing inductively couples plasma-atomic emission spectrometry:Part Ⅰ-Profile characteristics and flagging efficiency[J].Anal.Chem., 2012, 85(1):50-57.,2012.
[6] Chan G C, Hieftje G M.Spatial emission profiles for flagging matrix interferences in axial-viewing inductively coupled plasma-atomic emission spectrometry:Part Ⅱ-Statistical protocol[J].Anal.Chem., 2013, 85 (1):58-65.,2013.
[7] Chambers D M, Poehlman J, Yang P, et al.Fundamental studies of the sampling process in an inductively coupled plasma mass spectrometer[J].Spectrochimica Acta Part B:Atomic spectroscopy, 1991, 46(6):741-784.,1991.
[8] Taylor N, Spencer R L, Farnsworth P B.The effect of matrix composition on radially resolved argon metastable atom populations in an emission ICP[J].J.Anal.At.Spectrom., 2012, 27(5):857-867.,2012.
[9] Macedone J H, Gammon D J, Farnsworth P B.Factors affecting analyte transport through the sampling orifice of an inductively coupled plasma mass dpectrometer[J].Spectrochimica Acta Part B:Atomic Spectroscopy,2001, 56(9):1687-1695.,2001.
[10] Montaser A, Golightly D W.Inductively coupled plasmas in analytical atomic spectrometry[M].2nd Ed.[S.I.]:Wiley-VCH Publisher Inc., 1992.,1992.
[11] Macedone J H, Farnsworth P B.Changes in plasma composition during the expansion into the first vacuum stage of an inductively coupled plasma mass spectrometer[J].Spectrochimica Acta Part B:Atomic spectroscopy, 2006, 61(9):1031-1038.,2006.
[12] Mills A A, Macedone J H, Farnsworth P B.High resolution imaging of barium ions and atoms near the sampling cone of an inductively coupled plasma mass spectrometer[J].Spectrochimica Acta Part B:Atomic Spectroscopy, 2006, 61(9):1039-1049.,2006.
[13] Macedone J H, Mills A A, Farnsworth P B .Optical measurements of ion trajectories through the vacuum interface of an inductively coupled plasma mass spectrometer[J].Appl.Spectrosc.,2004,58(4):463-467.,2004.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%