欢迎登录材料期刊网

材料期刊网

高级检索

采用恒电位法、电化学阻抗谱和电化学噪声技术测量了2205双相钢的临界点蚀温度,同时对不同的电化学测量方法进行了比较.结果表明:恒电位法测得的数据波动范围较小且不易受外界信号干扰;电化学阻抗谱可以在一定程度上分析点蚀过程的机理;电化学噪声技术可以对数据进行监控并且不会对试样表面造成损伤.

参考文献

[1] Bo Deng;Yiming Jiang;Jia Gong;Cheng Zhong;Juan Gao;Jin Li.Critical pitting and repassivation temperatures for duplex stainless steel in chloride solutions[J].Electrochimica Acta,200816(16):5220-5225.
[2] P. J. Antony;Shobhana Chongdar;Pradeep Kumar;R. Raman.Corrosion of 2205 duplex stainless steel in chloride medium containing sulfate-reducing bacteria[J].Electrochimica Acta,200712(12):3985-3994.
[3] N. Ebrahimi;M. Momeni;A. Kosari;M. Zakeri;M.H. Moayed.A comparative study of critical pitting temperature (CPT) of stainless steels by electrochemical impedance spectroscopy (EIS), potentiodynamic and potentiostatic techniques[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,2012Jun.(Jun.):96-102.
[4] Helmuth Sarmiento Klapper;Joachim Goellner.Electrochemical Noise From Oxygen Reduction On Stainless Steel Surfaces[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,20091(1):144-150.
[5] Tao Zhang;Danyang Wang;Yawei Shao;Guozhe Meng;Fuhui Wang.A new criterion to determine the critical pitting temperature (CPT) based on electrochemical noise measurement[J].Corrosion Science: The Journal on Environmental Degradation of Materials and its Control,2012may(may):202-210.