欢迎登录材料期刊网

材料期刊网

高级检索

采用UP 213 Nd:YAG固体激光剥蚀系统和X Series 2型ICP-MS,以NIST610为外标, Si为内标,分析了3个不同标准锆石样品GJ-1、Ple比ovice和Qinghu中元素的组成和分布。建立的方法分析USGS玄武岩标准玻璃样品BCR-2中的34种元素时,分析结果相对误差<10%的有22种元素,>25%的只有2种元素,相对标准偏差<10%的有31种元素。3个不同标准锆石样品微量元素测定结果表明:各锆石样品的微量元素变化范围较大,从Hf在Ple比ovice锆石样品中的最高值26099μg/g到La在GJ-1样品中的最低值0.0077μg/g,相差可达7个数量级;总体上Qinghu锆石样品中的各元素含量都明显高于GJ-1和Ple比ovice样品;3个锆石样品的稀土元素球粒陨石标准化曲线也显示了不同的轻重稀土元素分异和Ce、Eu的富集异常;但对于单一锆石,其配分模式相似,这同时也表明所测数据的准确性。

A method of UP 213 Nd:YAG solid laser ablation inductively coupled plasma-mass spectrometry ( LA-ICP-MS,Thermo Fisher X-Series 2 ) using NIST610 as external standard and Si as internal element was established and employed to analyze the composition and distribution of elements of three different zircons , GJ-1 , Ple?ovice and Qinghu.The method was applied to analyze one basalt standard glass (BCR-2,USGS) with the result showing that the relative errors of 22 elements are <10%,2 elements are >25%,and the relative standard deviations of 31 elements are <10 %.The analysis results indicated that the concentration of trace elements in three zircons covered a wide range,from the Hf's highest value of 26 099μg/g in Ple?ovice zircon to the La's lowest value of 0.007 7μg/g in GJ-1 zircon,which showing that the gap of concentrations covers seven orders of magnitude .On the whole,Qinghu had sig-nificantly higher concentration than GJ-1 and Ple?ovice.Rare earth element chondrite-normalized curve of three zircons showed different distribution patterns ,including different LREE and different enrichment of Ce ,Eu,while the distribu-tion pattern was similar for single zircon ,which also validated the accuracy of the measured data .

参考文献

[1] Günther D;Hattendorf B .Solid sample analysis using laser ablation inductively coupled plasma mass spectrometry[J].Trends in Analyt-ical Chemistry,2005,24(03):255-263.
[2] 胡圣虹,胡兆初,刘勇胜,罗彦,林守麟,高山.单个流体包裹体元素化学组成分析新技术--激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)[J].地学前缘,2001(04):434-440.
[3] 李长民.锆石成因矿物学与锆石微区定年综述[J].地质调查与研究,2009(03):161-174.
[4] Liu, YS;Hu, ZC;Gao, S;Gunther, D;Xu, J;Gao, CG;Chen, HH .In situ analysis of major and trace elements of anhydrous minerals by LA-ICP-MS without applying an internal standard[J].Chemical geology,2008(1/2):34-43.
[5] 贾泽荣,詹秀春,何红蓼,胡明月,樊兴涛,王广.激光烧蚀-等离子体质谱结合归一定量方法原位线扫描检测石榴石多种元素[J].分析化学,2009(05):653-658.
[6] Longerich HP.;Gunther D.;Jackson SE. .LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRIC TRANSIENT SIGNAL DATA ACQUISITION AND ANALYTE CONCENTRATION CALCULATION[J].Journal of Analytical Atomic Spectrometry,1996(9):899-904.
[7] Paul W. O. Hoskin;Trevor R. Ireland .Rare earth element chemistry of zircon and its use as a provenance indicator[J].Geology,2000(7):627-630.
[8] E.A. Belousova;W.L. Griffin;Suzanne Y. O'Reilly .Igneous zircon: trace element composition as an indicator of source rock type[J].Contributions to Mineralogy and Petrology,2002(5):602-622.
[9] 柳小明,高山,第五春容,袁洪林,胡兆初.单颗粒锆石的20 μm小斑束原位微区LA-ICP-MS U-Pb年龄和微量元素的同时测定[J].科学通报,2007(02):228-235.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%