欢迎登录材料期刊网

材料期刊网

高级检索

A GMR (giant magneto-resistive) spin valve sensor for magnetic recording has been designed in an attempt to solve the Barkhausen noise problem in small-sized GMR sensors. In this study, the GMR ratio of the top-pinned spin valve is optimized to a value of 13.2%. The free layer is magnetized perpendicular to the pinned layer by a CoCrPt permanent magnetic bias so that a linear magnetic field response can be obtained. An obvious improvement on performance is observed when the permanent magnetic bias is magnetized, while the GMR sensor has a steadier MR-H loop and a smaller coercive field.

参考文献

[1] Baibich M N,Broto J M,Fert A,et al.Giant magnetoresistance of (001)Fe/(001)Cr magnetic superlattice.Phys Rev Lett,1988,61:2472
[2] Wallash A.A study of voltage function,noise and magnetic in-stability in spin valve GMR recording heads.IEEE Trans Magn,1998,34(4):1450
[3] Tsang C H,Fontana R E Jr,Lin T,et al.Design,fabrication,and performance of spin-valve read heads for magnetic recording applications.IBM J Res Dev,1998,42:103
[4] Lamberton R,Seigler M,Pelhos K,et al.Current-in-plane GMR trilayer head design for hard-disk drives:characterization and extendibility.IEEE Trans Magn,2007,43:645
[5] Fernandez-Outon L E,Vallejo-Femandez G,Manzoor S,et al.Thermal instabilities in exchange biased materials.Journal of Magnetism and Magnetic Materials,2006,303:296
[6] Dobrynin A N,Prozorov R.Characteristic temperatures of exchange biased systems.J Appl Phys,2007,102:043902
[7] Zhu J G,Zheng Y,Liao S.Patterned exchange stabilized spin valve heads at very narrow track width.IEEE Trans Magn,2001,37:1723
[8] Parkin S S.Dramatic enhancement of interlayer exchange coupling and giant magnetoresistance in Ni81 Fe19/Cu multilayers by addition of thin Co interface layers.Appl Phys Lett,1992,61:1358
[9] Lee C L,Devasahayam A J,Hu C C,et al.Critical thickness effects of NiFeCr-CoFe seed layers for spin.IEEE Trans Magn,2004,40:2209
[10] Liu X,Li Z H,Li S T,et al.Preparation of longitudinally oriented CoCrPt thin film in GMR head at room temperature.IEEE Trans Magn,2008,44:2858
[11] Lu Z Q,Pan G.New domain biasing techniques for nanoscale magneto-electronic devices.Springer Series in Materials Science,2007,94:187
[12] Tsang C H,Fontana R E,Lin T,et al.Design,fabrication,and performance of spin-valve read heads for magnetic recording applications.IBM Journal of Research and Development,1998,42:103
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%