欢迎登录材料期刊网

材料期刊网

高级检索

Understanding the radiation background at the north crossing point (NCP) in the tunnel of BEPCII is crucial for the performance safety of the High Purity Germanium (HPGe) detector, and in turn of great significance for long-term stable running of the energy measurement system. Therefore, as the first step, a NaI(Tl) detector is constructed to continuously measure the radiation level of photons as background for future experiments. Furthermore, gamma and neutron dosimeters are utilized to explore the radiation distribution in the vicinity of the NCP where the HPGe detector will be located. Synthesizing all obtained information, the shielding for neutron irradiation is studied based on model-dependent theoretical analysis.

参考文献

[1] FU Cheng-Dong,MO Xiao-Hu.Significance of absolute energy scale for physics at BESⅢ[J].中国物理C(英文版),2008(10):776-780.
[2] MO Xiao-Hu,ZHANG Jian-Yong,ZHANG Tian-Bao,ZHANG Qing-Jiang,Achasov Mikhail,FU Cheng-Dong,Muchnoi Nikolay,QIN Qing,QU Hua-Min,WANG Yi-Fang,WU Jing-Min,XU Jin-Qiang,YU Bo-Xiang.Measurement of radiation dose at the north interaction point of BEPCⅡ[J].中国物理C(英文版),2009(10):914-921.
[3] MO Xiao-Hu,FU Cheng-Dong,ZHANG Jian-Yong,QIN Qing,QU Hua-Min,WANG Yi-Fang,XU Jin-Qiang,ZHANG Tian-Bao.Working principles of the energy measurement system at BEPC Ⅱ[J].中国物理C(英文版),2008(12):995-1002.
[4] McKeever SWS. .Optically stimulated luminescence dosimetry[J].Nuclear Instruments and Methods in Physics Research, Section B. Beam Interactions with Materials and Atoms,2001(1/2):29-54.
上一张 下一张
上一张 下一张
计量
  • 下载量()
  • 访问量()
文章评分
  • 您的评分:
  • 1
    0%
  • 2
    0%
  • 3
    0%
  • 4
    0%
  • 5
    0%